7.9 Time and/or date is incorrect
Cause Troubleshooting
Time and date is
incorrect
Set the correct time and date in the operating
system.
or
Set the correct time and date in the BIOS
Information menu, using System Date and
System T
ime respectively.
Note that the operating system may affect the
system time. For example, the operating
system time may deviate from the system
time under Linux, and would overwrite the
system time in the default setting on
shutdown.
The lithium battery is
discharged
If the date and time are still wrong after the server
has been switched of
f and back on again, replace
the lithium battery (see the "FUJITSU Server
PRIMERGY RX2540 M6 Upgrade and Maintenance
Manual") or contact our customer service team.
7.10 Temperature warning
A temperature warning is output to the hardware event log and OS event log,
or ServerView issues a notification of a temperature warning such as by a
popup message.
This warning is issued by ServerView when the ambient temperature exceeds
the upper limit of the temperature boundaries. The upper limit is 35 °C for
standard server and 40 °C or 45 °C with Advanced Thermal Design.