The TPM is activated via the BIOS (for more information, see the "D3891 BIOS
Setup Utility for FUJITSU Server PRIMERGY RX2540
M6 Reference Manual").
CAUTION
▶
When using the TPM, note the program descriptions provided by
the third party manufacturers.
▶
You must create a backup of the TPM content. To do this, follow the
third party manufacturer's instructions. Without this backup, if the
TPM or the system board is faulty, you will not be able to access
your data.
▶
If a failure occurs, please inform your service about the TPM
activation before it takes any action, and be prepared to provide
them with your backup copies of the TPM content.
3.2.4 Power supply unit (PSU)
The server can be equipped with:
–
Up to two AC PSUs
In its basic configuration the server has one PSU that adjusts automatically
to any mains voltage in the range of 100 V - 240 V (AC PSU Platinum) or
200 V - 240 V (AC PSU T
itanium). Besides the PSU, a second PSU can be
installed optionally to serve as a redundant power supply. If one PSU fails,
the second PSU in the redundant configuration ensures operation can
continue uninterrupted and the defective PSU can be replaced during
operation (hot-plug). The second PSU can be installed during operation.
–
Up to two DC PSUs
In its basic configuration the server has one PSU that adjusts automatically
to any mains voltage in the range of -40.5 V - -57 V (DC PSU -48 V) or 200
V - 380 V (HVDC PSU 380 V). Besides the PSU, a second PSU can be
installed optionally to serve as a redundant power supply. If one PSU fails,
the second PSU in the redundant configuration ensures operation can
continue uninterrupted and the defective PSU can be replaced during
operation (hot-plug). The second PSU can be installed during operation.
–
One AC PSU or DC PSU and one PSU dummy cover
Product description
RX2540 M6 Operating Manual 25