Disconnect all data communication cables from the utility sockets.
Disconnect the relevant cables from the server and all the peripherals.
For connecting or disconnecting LAN cables, the server does not
need to be powered of
f. To avoid loss of data teaming function has to
be enabled.
Information for ensuring electromagnetic compatibility
All data and signal cables must have suf
ficient shielding. The use of cable type
S/FTP Cat5 or higher is recommended.
Use of unshielded or badly shielded cables may lead to increased emission of
interference and/or reduced fault-tolerance of the device.
5.5.2 Connecting devices to the server
The connectors for external devices are on the front and rear of the server, see
"Connectors, controls, and indicators" on page 32.
For a remote installation using the ServerView Installation Manger a
LAN connection is necessary
.
Some of the devices that can be connected may require special
software, e.g. drivers (see the documentation for the connected device).
Starting up
70 Operating Manual RX2540 M6