Cause Troubleshooting
The ambient
temperature
exceeds the upper
limit of the
temperature
boundaries
Although continued use within the temperature
boundaries poses no problems within itself,
reconsider the surrounding environment conditions if
this log is output or if ServerView issues this
notification.
7.11 Added drive reported as defective
Cause Troubleshooting
RAID controller is
not configured for
this drive
The drive was probably installed when the system was
switched of
f.
Reconfigure the RAID controller for the drive using
the corresponding utility. Information is provided in
the documentation for the RAID controller.
or
Remove and reinstall the drive while the system is
switched on.
If the HDD/SSD continues to be shown as defective,
then replace it (see the "FUJITSU Server PRIMERGY
RX2540 M6 Server Upgrade and Maintenance
Manual").
7.12 Expansion cards or onboard devices not
recognized
When an expansion card is added, other expansion cards or onboard devices
might not be recognized.
Troubleshooting and tips