15. OTHER FUNCTIONS
15-5
INSTRUMENTS SETUP section
[Engine & Tank Automatic Setup]: The system will automatically detect engines and
tanks connected to the same network. This is the recommended method for setting up
engines and tanks.
[Engine & Tank Manual Setup]:
Graphic Instruments Setup:
[Graphic Instruments Setup] - [Maximum Boat Speed], [Maximum Wind Speed]
[Graphic Instruments Setup] - [Depth]
[Graphic Instruments Setup] - [Sea Surface Temperature]
Menu item Description Options (setting range)
[Engine & Tank
Automatic Setup]
See "Engine & Tank Automatic Setup" below.
[Engine & Tank
Manual Setup]
See "Engine & Tank Automatic Setup" on the next page.
[Graphic Instruments
Setup]
See "Graphic Instruments Setup" below.
Menu Item Description Options (setting range)
[Nickname] Change the nickname for the engine or tank.
[Used For Propulsion] Select which engine/tank is used to
calculate the distance which may be
traveled using the remaining fuel. [ON] uses
the engine/tank for calculations, [OFF]
ignores the engine/tank.
[ON], [OFF]
[Reset] Resets the engine/tank details to default [OK], [Cancel]
Menu Item Description Options (setting range)
[Maximum Boat Speed] Set the transducer’s maximum detectable
speed.
1 kn to 99 kn
[Maximum Wind Speed] Set the transducer’s maximum detectable
speed.
1 kn to 99 kn
Menu Item Description Options (setting range)
[Minimum Depth] Set the transducer’s minimum detectable
depth.
1 m to 19 m
[Maximum Depth] Set the transducer’s maximum detectable
depth.
20 m to 2000 m
Menu Item Description Options (setting range)
[Minimum Sea Surface
Temperature]
Set the transducer’s minimum detectable
temperature.
0.00°C to 99.99°C
[Maximum Sea Surface
Temperature]
Set the transducer’s maximum detectable
temperature.
0.01 to 99.99°C