EasyManua.ls Logo

GE ALPS - Page 355

GE ALPS
366 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GE Power Management
ALPS Advanced Line Protection System iii
INDEX
INDEX
C
C1 (Protection Settin
g
2019) ............................................ 2-46
C2 (Protection Settin
g
2020) ............................................ 2-46
CARRSTART (Protection Settin
g
1204).. 1-30, 2-23, 2-33, 2-60,
2-69
CASE ................................................................................ 3-1
CASE ASSEMBLY ............................................................. 3-1
CC
see CONTACT CONVERTERS
CC1 (General Settin
g
501) ................................................. 2-8
CC10 (General Settin
g
510) ............................................... 2-8
CC11 (General Settin
g
511) ............................................... 2-8
CC12 (General Settin
g
512) ............................................... 2-8
CC2 (General Settin
g
502) ................................................. 2-8
CC3 (General Settin
g
503) ................................................. 2-8
CC4 (General Settin
g
504) ................................................. 2-8
CC7 (General Settin
g
507) ................................................. 2-8
CC8 (General Settin
g
508) ................................................. 2-8
CC9 (General Settin
g
509) ................................................. 2-8
CHANGE BUS/STATION ID............................................ 11-12
CHANNEL RELEASE TIME
definition ....................................................................... 2-34
CHANNEL TEST .............................................................. 8-11
CIRCUIT BOARDS
bus card.......................................................................... 3-3
communications interface ................................................ 3-9
communications interface dia
g
ram ................................... 3-9
DSP/ANI board .............................................................. 3-11
i960 CPU board............................................................. 3-12
input ........................................................................ 3-6, 3-7
local user interface lo
g
ic .................................................. 3-6
locations ......................................................................... 3-3
ma
g
netics module ...........................................................3-3
output ............................................................................. 3-6
power supply................................................................. 3-10
CLOSE BREAKER ............................................................. 8-9
CLOSE BREAKER 1 ........................................................ 1-19
CLOSE BREAKER 2 ........................................................ 1-19
CLOSEANG (Protection Settin
g
1819) ......................1-48, 2-44
CLR KEY ........................................................................... 8-2
COMMUNICATIONS ........................................................ 1-20
ALPS modem ................................................................ 8-25
ASCII command list ....................................................... 12-2
ASCII interface......................................................8-23, 12-1
description .................................................................... 12-1
DNP 3.0 ..........................................................................C-1
interface board ................................................................ 3-9
modem connections/settin
g
s ..................................8-24, 8-25
modem connnections/settin
g
s ........................................ 8-25
null-modem connections ........................................8-23, 8-27
passwords..................................................................... 8-21
remote communications interface ................................... 8-24
software ........................................................................ 8-23
COMPENSATED POSITIVE-SEQUENCE OVERVOLTAGE
application .................................................................... 1-44
description .................................................................... 1-44
phasor dia
g
ram ............................................................. 1-44
COMPENSATED SYSTEMS
Zone 1
g
round reach settin
g
.......................................... 2-11
Zone 1 settin
g
s ............................................................... 2-9
COMPENSATION FACTOR ................................................ 7-2
COMPORT1 (General Settin
g
201) ..................................... 2-4
COMPORT2 (General Settin
g
202) ..................................... 2-5
COMPORT3 (General Settin
g
203) ..................................... 2-5
CONFGTRIP (Protection Settin
g
810) ............................... 2-30
CONFIGURATION
outputs ..........................................................................1-10
CONFOSC (Protection Settin
g
2026)........................ 1-16, 2-47
CONFTRIP (Protection Settin
g
2025) ................................2-47
CONNECTING
to & lo
gg
in
g
out of device ...............................................11-9
CONSTRUCTION ........................................................3-1, 3-6
CONTACT CONVERTERS
calculation of settin
g
s ......................................................2-8
default assi
g
nments .........................................................1-9
di
g
ital output test ...........................................................8-12
input fla
g
s......................................................................13-4
protection settin
g
s ...........................................................2-8
status ............................................................................8-18
CONTACT RATINGS ..........................................................7-1
CONTINUOUS MONITOR .................................................1-22
CONTRAST......................................................................8-15
COUNTERS .....................................................................13-3
CS28A .............................................................................1-30
interconnection dia
g
ram for blockin
g
scheme ..................1-32
CS61C .............................................................................1-23
interconnection dia
g
ram for blockin
g
scheme ..................1-32
CT RATIO
see CURRENT TRANSFORMER RATIO
CTRATIO (Protection Settin
g
1407)...................................2-37
CURRENT SUPERVISION FUNCTION ................................7-1
CURRENT TRANSFORMER RATIO
settin
g
...........................................................................2-37
CURRENT UNBALANCE DETECTION...............................1-16
CURVES
extremely inverse curve .................................................2-50
inverse curve .................................................................2-48
very inverse curve..........................................................2-49
CUSTOM PROGRAMMABILITY ..........................................1-9
D
DATE/TIME
modifyin
g
.........................................................................8-7
DBUSDLINE (Protection Settin
g
1838) ..............................2-45
DBUSLLINE (Protection Settin
g
1837)...............................2-45
DEFTIMDELY (Protection Settin
g
616) ..............................2-27
DELTAV (Protection Settin
g
1839) ...........................1-48, 2-45
DELTAVBLK (Protection Settin
g
1840) .....................1-48, 2-46
DESCRIPTION ...................................................................1-4
DEVICE PROFILE DOCUMENT (DNP 3.0) ......................... C-2
DIGITAL INPUT TEST ........................................................4-9
DIGITAL INPUTS
see CONTACT CONVERTERS
DIGITAL OUTPUTS
power supply board........................................................3-10
test.............................................................................. 11-13
DIGITAL-TO-ANALOG CONVERTER
see SCADA DTA
DIMENSIONS.....................................................................7-2
DISABLE OUTPUTS
with ALPS-Link ............................................................ 11-12
with keypad .....................................................................8-8
DISPLAY
contrast .........................................................................8-15
description.......................................................................8-1
messa
g
es ........................................................................8-3
DISPLAYVAL (General Settin
g
108) ....................................2-4
DISTANCE FUNCTIONS
maximum allowable reach ..............................................2-13
Xpression Builder fla
g
s ..................................................13-6
Zone 1......................................................................1-4, 2-9
Zone 2...........................................................................2-14

Table of Contents