ADV100 • Functions description and parameters list 109
5 Mdplc 16
6 Mdplc 32
7 Eu
8 Eu oat
9 Par 16
10 Par 32
If set to 0 the channel is not assigned.
If set to 1 the datum is assigned a 16-bit count.
If set to 2 the datum is assigned a 32-bit count.
If set to3 16 bits on the channel are reserved for the datum, not used.
If set to 4 32 bits on the channel are reserved for the datum, not used.
If set to5 the datum is assigned a 16-bit count used by MDPLC.
If set to 6 the datum is assigned a 32-bit count used by MDPLC.
If set to 7 the datum is assigned engineering units on a 16-bit integer.
If set to 8 the datum is assigned engineering units on a 32-bit integer.
If set to 9, the datum is assigned a 16-bit integer engineering unit format not in real time (5-10ms)
If set to 10 the datum is assigned a 32-bit integer engineering unit format or oat format if the associated parameter
is a oat-type parameter not in real time (5-10ms)
Note ! If the sys parameter is notassigned, none of the subsequent channels are transferred to the fieldbus, even if pro-
grammed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.4.3 4184 DigFieldbusS->M1 INT32 32 0 0 0 ERW FVS
23.4.7 4194 DigFieldbusS->M2 INT32 32 0 0 0 ERW FVS
23.4.11 4204 DigFieldbusS->M3 INT32 32 0 0 0 ERW FVS
23.4.15 4214 DigFieldbusS->M4 INT32 32 0 0 0 ERW FVS
23.4.19 4224 DigFieldbusS->M5 INT32 32 0 0 0 ERW FVS
23.4.23 4234 DigFieldbusS->M6 INT32 32 0 0 0 ERW FVS
23.4.27 4244 DigFieldbusS->M7 INT32 32 0 0 0 ERW FVS
23.4.31 4254 DigFieldbusS->M8 INT32 32 0 0 0 ERW FVS
23.4.35 4264 DigFieldbusS->M9 INT32 32 0 0 0 ERW FVS
23.4.39 4274 DigFieldbusS->M10 INT32 32 0 0 0 ERW FVS
23.4.43 4284 DigFieldbusS->M11 INT32 32 0 0 0 ERW FVS
23.4.47 4294 DigFieldbusS->M12 INT32 32 0 0 0 ERW FVS
23.4.51 4304 DigFieldbusS->M13 INT32 32 0 0 0 ERW FVS
23.4.55 4314 DigFieldbusS->M14 INT32 32 0 0 0 ERW FVS
23.4.59 4324 DigFieldbusS->M15 INT32 32 0 0 0 ERW FVS
23.4.63 4334 DigFieldbusS->M16 INT32 32 0 0 0 ERW FVS
If associated with the relative src, the value of this parameter is sent to the bus.
The user may modify the M->S and by S->M sys parameters. The consistency of the sys with the parameter as-
signed to the channel is checked.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.4.4 4186 FieldbusS->M1mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.8 4196 FieldbusS->M2mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.12 4206 FieldbusS->M3mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.16 4216 FieldbusS->M4mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.20 4226 FieldbusS->M5mul FLOAT 1.0 1.0 1000.0 ERW FVS