ADV100 Functions description and parameters list 39
10–MONITORFUNCTION
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
10.1 930 Reference0thr rpm INT16 30 0 CALCI RW FVS
Setting of the threshold for recognition of the speed = 0 reference. The value is valid for both directions of rotation.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
10.2 932 Reference0delay ms UINT16 400 0 10000 RW FVS
Setting of the delay in milliseconds after which the reference = 0 reached signal is enabled.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
10.3 940 Speed0thr rpm INT16 30 0 CALCI RW FVS
Setting of the threshold for recognizing speed value = 0. The value is valid for both directions of rotation.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
10.4 942 Speed0delay ms UINT16 400 0 10000 RW FVS
Setting of the delay in milliseconds after which the speed = 0 reached signal is enabled.
When the motor reaches a speed that is below the zero speed threshold, it stops and the
n= 0
LED lights up.

Table of Contents

Other manuals for gefran SIEIDrive ADV100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran SIEIDrive ADV100 and is the answer not in the manual?

gefran SIEIDrive ADV100 Specifications

General IconGeneral
Brandgefran
ModelSIEIDrive ADV100
CategoryController
LanguageEnglish

Related product manuals