ADV100 Functions description and parameters list 71
19–REGULATORPARAM
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
19.1 2250 CurrentregPgain V/A FLOAT CALCF 0.0 0.0 ERWS F_S
Setting of the proportional coefcient of the current regulator.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
19.2 2252 CurrentregItime ms FLOAT CALCF 0.01 10000.0 ERWS F_S
Setting of the integral coefcient of the current regulator.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
19.3 2260 FluxregPgain A/Wb FLOAT CALCF 0.0 0.0 ERWS F__
Setting of the proportional coefcient of the ux regulator.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
19.4 2262 FluxregItime ms FLOAT CALCF 0.01 10000.0 ERWS F__
Setting of the integral coefcient of the ux regulator.