70 ADV100 Functions description and parameters list
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
18.15 2240 Inertia kgm
2
FLOAT SIZE 0.001 100.0 RWZS F_S
Setting of the inertia compensation coefcient. An increase in the dynamic response of the speed regulator to a vari-
ation in the reference, can be modied by changing the current value during the acceleration/deceleration phase, to
counter the applied machine inertia.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
18.16 2242 Bandwidth rad/s FLOAT SIZE 1.0 500.0 RWZS F_S
Setting of the bandwidth. Increasing the setting of this parameter increases the dynamic response and makes the
system more rigid.