ADV100 • Functions description and parameters list 19
Note ! The LoadDefaultcommand (par. 580) does not modify this parameter.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.15 580 Loaddefault BIT 0 0 1 RWZ FVS
Transfers the standard factory settings to the drive memory (“Def” column in the parameters table).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.16 590 Savepartokeypad BIT 0 0 1 RW FVS
Transfers the parameters currently stored in the drive and saves them in the keypad memory (See ADV100 Quick
Start manual, chapter 6.8).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.17 592 Loadparfromkeypad BIT 0 0 1 RWZ FVS
Transfers the parameters from the keypad memory to the drive (See ADV100 Quick Start manual, chapter 6.9).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.18 594 Keypadmemoryselect UINT16 1 1 5 ERW FVS
Selection of the area of the keypad memory to which to transfer and save the parameters stored in the drive.
Menu PAR Descrizione EU Tipo FB BIT Def Min Max Acc Mod
4.19 596 Salvapar->cardSD BIT 0 0 1 RW FVS
Transfers the drive parameters to the SD memory card (See chapter 8.9 of the Quick start-up guide).
Menu PAR Descrizione EU Tipo FB BIT Def Min Max Acc Mod
4.20 598 Caricapar<-cardSD BIT 0 0 1 RWZ FVS
Transfers the parameters from the SD memory card to the drive (See chapter 8.9 of the Quick start-up guide).