18 ADV100 • Functions description and parameters list
one and Saveparameters.
After entering the password, press the E key once to enter it into the memory and again to enable it (= Enabled is
displayed to indicate that the password is enabled).
So that the password remains valid even after switching the unit off and then switching it back on, save it using the
Saveparameters command.
When the password is enabled any attempts to modify a parameter are blocked and the Passwordenabled mes-
sage is displayed.
To disable the password, enter the Password parameter (572) in the DRIVECONFIG menu.
Check that the password is enabled (Enabled), press E and enter the combination of gures that make up the pass-
word.
Press E again. A message is displayed telling you the password is no longer enabled (Disabled).
To make sure the password continues to be disabled even after switching the unit off and then switching it back on,
save this conguration using the Saveparameters command.
When an incorrect password is entered, the Password wrong message is displayed
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.11 572 Applicationkey UINT32 0 0 4294967295 ERW FVS
This parameter can be used to enter the key for enabling the PLC application.
You may need to enter a key to denitively enable some PLC applications. Please contact Gefran for details about
which PLC applications require the key.
If executing an application that envisages a key verication and the key is incorrect, enabling is forced for 200 hours
(time drive enabled).
In this phase a message is displayed informing you that the period of forced enabling time is about to expire.
At the rst power-on after the 200 hours an alarm is generated and the application does not start.
Please contact Gefran for the numerical value of the key.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.12 574 Startupdisplay INT16 -1 -1 20000 ERW FVS
This is used to set the parameter that will be displayed automatically at drive power-on. Entering the value -1 (de-
fault), the function is disabled and the main menu is displayed at power-on.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.13 576 Displaybacklight BIT 0 0 1 ERW FVS
Enabling of the backlight on the drive display.
If set to 0 the display backlight will go off when the drive has been on for three minutes.
If set to 1 the backlight will stay on for as long as the drive is powered.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4.14 578 Languageselect ENUM English 0 9 RWZ FVS
Setting of the drive programming language.
0 English
1 Italian
2 French
3 German
4 Spanish
5 Polish
6 Romanian
7 Russian
8 Turkish
9 Portuguese