ADV100 • Functions description and parameters list 59
Vout output voltage on the card terminals.
StpVar actual value of the variable (variable unit)
SFVar full scale of the variable (variable unit)
Example of calculation of the AnalogoutXxscalefactor
To display the drive speed, use an analog instrument with eld of measurement from 0 ... 2V. This means that, to
display the speed of the drive, a voltage of 2V on the analog output of the drive must correspond to the maximum
speed. With a scale factor of 1 this would be 10V (Scale factor = 2V / 10 V = 0.200).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
15.5 1866 Analogout1Xmon cnt INT16 0 0 0 ER FVS
The actual value of the voltage present on analog output 1 of the expansion card is displayed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
15.6 1868 Analogout2Xmon cnt INT16 0 0 0 ER FVS
The actual value of the voltage or current present on analog output 2 of the expansion card is displayed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
15.7 1874 Anout1Xabsolute ENUM Disable 0 1 ERW FVS
15.8 1876 Anout2Xabsolute ENUM Disable 0 1 ERW FVS
Enables the relative analog output as an absolute value. If this parameter is set to 1 the voltage on the analog output
assumes the value of 0 - 10V regardless of the sign of the command signal.
0 Disable
1 Enable
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
15.9 1882 Analogout1Xmin cnt INT16 -16384 -32768 +32767 ERW FVS
15.10 1884 Analogout1Xmax cnt INT16 16384 -32768 +32767 ERW FVS
Setting of the minimum and maximum values for the analog output for the voltage present on analog output 1 of the
expansion card.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
15.11 1890 Analogout2Xmin cnt INT16 -16384 -32768 +32767 ERW FVS
15.12 1892 Analogout2Xmax cnt INT16 16384 -32768 +32767 ERW FVS
Setting of the minimum and maximum values for the analog output in current or voltage present on analog output 2
of the expansion card.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
15.13 1898 Analogout2Xtype ENUM -10V..+10V 0 2 ERW FVS
Selection of the programmed signal on analog output 2 of the expansion card. Depending on the output signal, move
the switch on the regulation card. The standard output is coded for the signal in voltage.
0 -10V..+10V
1 0,20mA … 10V
2 4..20mA
Select option 0 in order to apply a maximum voltage of ±12.5V (typically ±10V/5mA) to analog output 2.
Select option 1 in order to apply a maximum voltage of +10V or a signal in current of 0 ... 20 mA to analog output 2.
The signal must be positive.
Select option 2 to apply a signal in current of 4...20 mA to analog output 2.