6 ADV100 • Functions description and parameters list
Practicalexample
The following examples illustrate the philosophies and methods with which more or less complex operations are
performed in the single “function blocks”, the results of which represent the output of the block.
• Example: Changing the Speed Reference source
The main drive reference (in the default conguration) Rampref1mon(PAR: 620) is generated by the output of the
function block “RampsetpointBlock”.
Its default source is the Analoginput1Xmon signal (PAR: 1600), from the output of the function block “Analog
input1Block”, which in this case refers to analog input 1 of the signal terminal strip.
To change the reference source from the analog input to a digital reference inside the drive, the input signal must be
changed to “RampsetpointBlock”.
Enter the Rampref1srcparameter (PAR: 610)and set a new reference, selecting it from among those listed in the
L_MLTREF selection list, for example Digrampref1(PAR: 600).
• Example: Inverting the analog reference signal
To invert the “Analoginput1Block” output signal, the value of the Aninp1signsrcparameter (PAR: 1526),
which has a default setting of Null (no operation), must be changed by selecting the source of the command signal
from among those listed in the L_DIGSEL 2 selection list, for example DigitalinputXmon, One(function always
enabled), etc.
+1
-1
* -1
* +1
Null
Null
An inp 1 sign src
Null
An inp 1 alt sel src
Analog input 1 mon
Analog input 1 Block
Ramp Setpoint Block
Terminal input
Ramp ref 1 mon
Ramp ref 1 src
An inp 1 alt value
Ramp ref invert src
The diagrams above illustrate the internal processing philosophy of the single “function blocks” and the result of
these changes on the other interconnected “function blocks”.
Note ! This section contains a brief description of the functions of the other parameters in the function blocks not included
for the changes in the example
The Aninp1Xaltselsrc parameter (PAR: 1628) can be used to select an alternative reference for the Analog
input1Xmon(PAR: 1600) output.
The Aninp1Xaltvalueparameter (PAR: 1624) determines the alternative reference value for the Analoginput1X
mon(PAR: 1600) output.
The Ramprefinvertsrc parameter (PAR: 616) can be used to select the source for the command to reverse the
“Rampsetpoint” function block output.
The output signal from the “Rampsetpoint” block is displayed in the Rampref1monparameter (PAR: 620).