VRC2000 Installation and Operations Manual Page 111
Technical or Setup Assistance
Telephone: 800.945.7730 (USA) or 801.975.7200 (worldwide) • Worldwide Web @ http://www.gentner.com
Now you can enter commands using the telephone DTMF pad that will cause
the VRC2000 to take readings, report pending alarms or activate command-
channel outputs.
To check on pending alarms, enter the following sequence on your DTMF
pad:
☎ “0 0 0”
The VRC2000 will respond:
• NO ALARMS PENDING.
ALARMS PENDING NOTE:
No alarms are pending since the VRC2000 has not yet been set up for alarm
reporting. Instructions for setting up alarms are covered in VRC2000 Setup
(Page 10). If the VRC2000 reports an alarm at this point, make a note of exactly
what the unit says.
Now enter the following sequence on your DTMF pad:
☎ “1 1 1”
The VRC2000 will respond:
• ERROR.
The sequence just entered is not a valid instruction. Whenever you hear an
ERROR message, wait a second and then re-enter a valid sequence.
Now enter
☎ “6 0 1 *”
The VRC2000 will respond:
• METERING CHANNEL ONE ... POINT ZERO, ZERO, ZERO, ZERO, VOLTS.
The VRC2000 is reporting the current input condition of metering channel l.
Since the VRC2000 has not been fully set up yet, no further message will be
heard. After the unit is set up, the VRC2000 will tell you the exact electrical
condition of metering channel 1.
Now enter
☎ “6 1 6 *”
The VRC2000 will respond:
• METERING CHANNEL SIXTEEN ... POINT ZERO, ZERO, ZERO, ZERO, VOLTS.
Now enter
☎ “7 0 1 *”
The VRC2000 will respond with the current condition of status channel l.