EasyManua.ls Logo

Gerber Dimension 200 - Weekly Inspection; Weekly Cleaning; Z Axis Ways

Default Icon
111 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
100 Dimension 200
Weekly Inspection
Component What To Check For
Z axis ways
Debris buildup
X and Y axis ways
Debris buildup
Electrical box air filter
Debris buildup on filter
element
Weekly Cleaning
The weekly cleaning and maintenance procedures include the
following:
cleaning and oiling the ways
cleaning the electrical box air filter
Z AXIS WAYS
1.
Locate the Z axis ways on either side of the router motor.
2.
Lower the router motor to its lowest position by turning the Z
axis adjustment knob.
3.
Clean and oil the upper part of the Z axis ways.
4.
Use a lint-free cloth to clean the way.
5.
Lightly oil the Z axis way with light machine oil.
6.
After cleaning the upper part of the Z ways, raise the router
motor to its highest position by turning the Z axis adjustment
knob.
7.
Clean and oil the lower part of the Z axis ways.
8.
Use a lint-free cloth to clean the way. Lightly oil the way.

Table of Contents