Optional Equipment Installation 31
10.
Attach the other end of the hose to the vacuum blower with a
2" barb adapter, cutting the hose as short as possible to
increase the efficiency of the blower. Secure with a hose
clamp.
11.
Have a licensed industrial electrician with industrial motor
experience wire the vacuum blower.
Speed Controller System
Refer to the illustration below when installing the Speed
Controller System:
To install the Speed Controller System
1.
Plug the AC power cord into a dedicated wall outlet.
2.
Plug the Spindle remote ON/OFF cable labeled P894 into the
connector labeled R894 (top) on the back of the electrical box.
3.
Plug the Spindle Motor cable into the connector located on the
High Frequency Spindle motor and latch it.

Table of Contents