EasyManua.ls Logo

GRAPHTEC FC4100 series - RS-232 C Data Transmitting Conditions

GRAPHTEC FC4100 series
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting the Interface Functions C7 - 4
STEP SIZE>
RS-232C>
COMMAND>
RS-232C \1>
CONDITION NO. 2>
3>
RS-1 9600 BAUD
8 BIT
NONE PARITY
HARDWIRE
RS-232C – Setting the Data Transmitting Conditions
This function selects and sets the data transmitting condition of the serial interface. Three preset
conditions are available for easy access.
NOTE: Be sure to set the transmitting conditions to match the setting of your software
applications
NOTE: Your RS-232C setting is retained in the plotter’s internal memory while the plotter is
turned off.
Press F3 key to select RS-232C.
Press the F1 key to select factory setting 1.
Press the F2 key to select factory setting 2.
Press the F3 key to select factory setting 3.
The asterisk is displayed beside the currently selected
condition number.
The menu that corresponds to the number you selected will appear
RS-1 9600 BAUD RS-2 9600 BAUD RS-3 9600 BAUD
8 BIT 7 BIT 8 BIT
NONE PARITY EVEN PARITY EVEN PARITY
HARDWIRE HARDWIRE HARDWIRE
You can modify any of the RS232-C settings by pressing the F1, F2, F3 or F4 key. The blinking
cursor will move to the parameter that corresponds with that key.
Press the F1 key to change BAUD RATE.
Press the F2 key to change DATA LENGTH.
Press the F3 key to change PARITY BIT.
Press the F4 key to change HANDSHAKING.
Press the UP or DOWN ARROW key to change the
parameter’s setting.
Press the ENTER key to register your settings and
return to the INTERFACE menu.

Table of Contents