Unreferenced_PID
34A1
PID not referred to by a PMT or a CAT within 0,5
s
STD_error
35A1
Sections of the current SDT table not present in
the TS in a period of time longer than the
threshold
35A2
Found tables different to SDT, SDT2, BAT or ST
in the packets with PID 11
35A3
The interval of time between two consecutive
sections of the SDT table is shorter tan
threshold
35A4
The SDT table does not exist. The search time
is showed in the alarm 3.5.A.1
35B1
The interval between two equal sections of the
SDT table (other) is greater than the threshold
EIT_actual_error
36A1
Section 0 of the current EIT table is not present
for a longer time than the threshold
36A2
Section 1 of the current EIT table is not present
for longer time than the threshold
36A3
Found tables with TID out of range 4e 6f or 72
in packets with PID 12
36A4
The interval of time between two consecutive
sections of the EIT table is shorter than
threshold
36A5
EIT table does not exist and it should
EIT_other_error
36B1
Section 0 of the EIT2 table (other) is not present
for a period of time longer than the threshold
36B2
Section 1 of the EIT2 table (other) is not present
for a period of time longer than the threshold
EIT_PF_error
36C1
If either section (‘0’ or ‘1’) of each EIT P/F
subtable is present both should exist. Otherwise
this error will be indicated
RST_error
37A1
Found a table different to RST or ST in the
packets with PID 13
37A2
The interval of time between two consecutive
sections of the RST table is shorter than
threshold
TDT_error
38A1
The interval between any two sections of the
DTT table is greater than the threshold
38A2
Found a table different to DTT, ST or TOT table
in packets with PID 14
38A3
The interval of time between two consecutive
sections of the TDT table is shorter than
threshold
38A4
TDT table does not exist. The search time is
shwed in the alarm 3.8.A.1
Empty_buffer_error
39A1
TB buffer not flushed at least once per second
39A2
Tbsys buffer not flushed at least once per
second
39A3
MB buffer not flushed at least once per second
Data_delay_error
3AA1
Data delay through buffers is greater than 1
second