At the bottom there is a list of all recordings stored in the memory. On the right side of the name of
the file, it is shown its size, as well as three buttons: the first one allows to delete the file, the second
one allows to download the file to the computer, and the third one allows to save the file in a USB
memory connected to the RCS.
4.4.- T2MI Templates –Only for RCS100 and RCS400-
This feature allows you to create a T2MI signal template by selecting the value for each of its
parameters. This way, when the RCS receives a signal with values different from the template, the
equipment will generate an alarm.
For the alarm to be triggered, in addition to setting up the template, you must enable the
corresponding alarm in the section RF alarms. See section 8.- Alarms.
NOTE 1: Since the RCS is turned on there is an interval of one minute in which
no events will be recorded.
NOTE 2: No more than one event will be recorded every minute.