When the system is in polling mode, the stabilization margin is provided by the number of cycles
during which a measurement is out of the thresholds (Cycles ON). In the polling mode, the alarms
configuration works in the same way for both transport and RF measurements.
The number of cycles may be between 1 and 120. So, the Cycles ON parameter indicates the
number of polling cycles during which a measurement must be out of the thresholds for the system
to generate the activated alarm warning.
Once the measurement is back within the thresholds, the alarm-off message is generated
immediately.
The PID bitrates alarms profiles must be explained separately:
The user must indicate for each profile the max and min values of the bitrate range. When the
bitrate is out of this range, the system generates an alarm. See section 3.1.- Bitrate to know how to
assign the profiles.
1.5.2.- Bitrate Measure Profile
Allows to enable the bitrate measure profiles.
Measurement threshold
Time axis
Threshold-Hysteresis
Alarm-on periods of time
Alarm-on
Alarm-off
Alarm-on
Alarm-off