© Guldmann GB/US-09/2016 • #550376_3
6
GENERAL INFORMATION
General conditions
Product liability
In relation to product liability the current rules under Danish
law shall apply.
The Seller shall never be held liable for operating losses,
loss of earnings and other indirect losses.
Product liability insurance which includes cover against
injury and property damage has been taken out.
Any disputes between the parties shall be settled by the
Maritime and Commercial Court in Copenhagen (Sø- og
Handelsretten) in pursuance of Danish law
Transport and storage
Transport and storage must be in the range of limited
environmental condition:
Temperature between -10 and +40°C / 14 and 104°F
Relative air humidity between 30 and 70 %
Air pressure between 70 and 106 kPa
(See symbols page 8)
Warning!
Do not modify this equipment without authorization of the
manufacturer.
Installation in corrosive surroundings
Special guidelines must be observed when installing the
rail system around swimming pools, etc.
The surfaces of the brackets used, traverse travelling
trolleys, etc., must be painted. Hoists must be supplied
with a special surface treatment.
All fixing elements, nuts, washers, threaded rods, must be
acid-proof.
Acid-proof threaded rods and dual-component adhesive
must be used for installation in concrete, tiles, etc.
Through-going threaded rods or acid-proof screws must
be used for installation in wood.
Particular care should be taken to avoid damaging the
surface of painted components.
Washers made of synthetic material must be used in
between painted surfaces and nuts and ordinary washers.
Damaged paint must be repaired after installation, and
visible threaded rods, nuts, washers, etc., must be covered
with paint.
Hidden threaded rods, nuts, washers, and brackets in the
rail track must be treated with a silicone coating.
Wherever possible, nuts must be fitted with protective
caps.
There must be no swarf, dirt, or other impurities in the
rail system as they will accumulate moisture and lead to
corrosion.
Bearings in traverse travelling trolleys must be treated with
a silicone coating before installation.
Guldmann recommends that in corrosive surroundings like
swimming pools, bathing environments etc., regular safety
and service inspection at rail systems and ceiling hoists
must be performed every ½ year. A complete overhaul of
the rail system (replacements of brackets, fixings etc.) can
be necessary approx. every 5 year.
Guldmann products are designed for use in these environ-
ments with the following maximum values of;
Water quality:
pH....................................... 7,6
Free chlorine, mg/l .......................... 2,0
Bound chlorine, mg/l ........................ 0,5
Air humidity:
The relative air humidity in the room should be approx.
70% at an outdoor temperature of approx. 20 degree C
and approx. 50% at an outdoor temperature of approx.. 0
degree C.
Note!
Quality designation for bolts, etc.
A4/AISI 316 = acid-proof
A2/AISI 304/rustproof 18.8 = not acid-proof
Torque settings
All bolts and nuts are tightened with torque in accordance
with applicable rules – M8 = 27 Nm, M10 = 54Nm.
Hilti HUS-H 8 x 65 screws are tightened with a torque of
35 Nm.
Hilti HUS-H 8 x 85 – 150 screws are tightened with a torque
of 45 Nm.
The two M10 nuts at the GH Plasterboard Wall bracket are
thightened with a torque of 30Nm.