EasyManua.ls Logo

Guldmann GH - Service Manual

Guldmann GH
168 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
23W123W1
GENERAL INFORMATION
SERVICE AND REPAIR
TECHNICAL DRAWINGS
CONTROL
Guldmann develops, manufactures,
distributes and maintains products and
services that make the daily lives
of disabled people and their
carer a little easier.
SERVICE GUIDE
FOR GH
Vers. 3.00

Table of Contents

Questions and Answers

  • B
    barbara34Aug 20, 2025
    What to do if Guldmann Mobility Aid shows fault 16/20?
    • A
      Anthony WilliamsAug 20, 2025
      If your Guldmann Mobility Aid displays fault 16/20, which indicates a fault on the motor brake on the leader-leader PCB or motor, here’s what you can do: First, check the position of the handle. Then, check the cables and micro switch by pulling the emergency strap to see if the brake releases (you should hear a click). If it does, replace the PCB. If not, inspect the cable and connection (J12) or consider replacing the motor/gear.
  • T
    Tyler WilliamsAug 21, 2025
    What to do if Guldmann Mobility Aid is not charging 16?
    • T
      Tristan MontoyaAug 21, 2025
      If your Guldmann Mobility Aid is not charging (16), and the issue stems from the leader charger, take these steps: Check the power from the charging liner and power supply. Inspect the connection between the charger PCB (J4) and the motor safety PCB (J20 on 16). Also, verify the connection between the battery and charger (J3). If these are all in order, consider changing the charger PCB.
  • N
    Natalie WilliamsAug 23, 2025
    What to do if Guldmann Mobility Aid shows fault 18/1?
    • B
      Breanna BlakeAug 25, 2025
      If your Guldmann Mobility Aid displays fault 18/1, indicating a communication fault with the twin hoist, you can try the following: Check the cables and connection between the PCB on the leader hoist (J10/J11 on 16) and the follower hoist (J10/J11 on 18). Verify the battery voltage on (18), ensuring it's at least 16 volts. Check the jumper settings on (18). If problems persist, replace the PCB on either (16) or (18).
  • R
    Richard SchwartzAug 26, 2025
    What to do if Guldmann Mobility Aid shows fault 17/1?
    • S
      Steven ChavezAug 26, 2025
      If your Guldmann Mobility Aid displays fault 17/1, which indicates a communication fault with the Follower PCB (17), here’s how to troubleshoot: Check the cables and connection between the leader and follower PCB (J10 on 16 to J10 on 17). Check that the LED is on (17). If the LED is on, check the jumper settings and consider replacing PCB (16) or (17). If the LED is off, check the battery voltage, ensuring it is a minimum of 16 volts, and verify the battery connection on (17). If these steps don't resolve the issue, replace (17).
  • A
    Anita KennedyAug 27, 2025
    What to do if Guldmann Mobility Aid shows fault 16/21?
    • T
      tiffany24Aug 27, 2025
      If your Guldmann Mobility Aid displays fault 16/21, indicating a fault on the tacho detection on the leader (16), you should: Check the cables and connection (J14 on 16). If the issue persists, consider replacing the motor (16) or replacing the PCB (16).
  • T
    thomas93Aug 29, 2025
    What to do if Guldmann Mobility Aid shows fault 18/21?
    • T
      traci93Aug 29, 2025
      If your Guldmann Mobility Aid displays fault 18/21, which indicates a fault on the tacho detection on the twin follower hoist (18), you can try the following: Check the cables and connection (J14 on 18). If problems persist, consider replacing the motor (18) or replacing the PCB (18).
  • L
    Lindsay SchneiderAug 31, 2025
    What to do if Guldmann Mobility Aid is not charging 18?
    • L
      Lorraine BrownSep 1, 2025
      If your Guldmann Mobility Aid is not charging (18), and it's related to the leader charger on the follower hoist of a Twin hoist, here’s what to check: Ensure there is power from the charging liner and power supply. Check the connection between the charger PCB (J4) and the motor safety PCB (J20 on 18). Verify the connection between the battery and charger (J3). If the problem continues, consider changing the charger PCB.
  • J
    Jason RoySep 2, 2025
    What to do if Guldmann Mobility Aid indicates low battery 16?
    • G
      Gina MorrisSep 3, 2025
      If your Guldmann Mobility Aid indicates a low battery on the leader (16), you can take the following steps: Check the connection between the battery and charger (J3). After checking the connection, charge the battery for ½-2 hours.
  • S
    Stacy SextonSep 5, 2025
    What to do if Guldmann Mobility Aid shows fault 16/22?
    • J
      Jamie BellSep 5, 2025
      If your Guldmann Mobility Aid displays fault 16/22, indicating a hardware overcurrent on the leader (16), you may need to: Replace the motor (16). If the problem persists, replace the PCB (16).
  • A
    Andrew CummingsSep 6, 2025
    What to do if Guldmann Mobility Aid shows fault 17/22?
    • J
      Joseph JohnsonSep 6, 2025
      If your Guldmann Mobility Aid displays fault 17/22, indicating a hardware overcurrent on the follower (17), you may need to: Replace the motor (17). If the problem continues, replace the PCB (17).

Summary

General Information

General Conditions and Information

Basic terms, legal aspects, and general guidelines for use and handling.

GH Lifting Modules and Rail Types

Details on hoist models, configurations, and available rail system types.

Service and Repair

GH3 Service Procedures

Step-by-step instructions for servicing and repairing the GH3 hoist.

GH1 Service Procedures

Step-by-step instructions for servicing and repairing the GH1 hoist.

Technical Drawings

Spare Part Overviews

Illustrated lists of spare parts for various hoist models.

Wiring and Electrical Diagrams

Schematics for hoist configurations, including jumper settings.

Control and Inspection

Hoist and Rail System Inspection Guidelines

Procedures for periodic safety inspections according to standards.

Sling Inspection Guidance

Safety procedures for inspecting lifting slings.

Guldmann GH Specifications

General IconGeneral
TypeCeiling Hoist
Lifting Speed0.12 m/s
Max Speed0.12 m/s
Control TypeHandheld Control
Safety FeaturesEmergency stop, overload protection

Related product manuals