EasyManua.ls Logo

Hamilton Jet HTX30 - Alarm and Warning Code Reference

Default Icon
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HTX30 Product Manual
Fault Finding
6-5
Jog right a third time to display the alarm sub-code.
Sub codes are described in the appendix and can be used to further diagnose the alarm's cause.
In the following example, sub-code 0 is shown.
To exit the alarm browser:
Press and hold the cancel button for 3 seconds, or
switch off power to the system.
Alarm and warning codes
This section includes a complete list of alarms and warnings.
Where the Station Control Panel (SCP) display text is separated by a forward slash / the display will alternate
between the two words.
Several alarms will cause the system to shut down and return the vessel to zero speed.
These alarms are:
BAKUP
Occurs when the system is switched into backup.
SETUP
Occurs when the system enters setup.
LOCAL
Occurs when control is taken at the local engine control panel.
DEMND/LOST
Occurs when the jet interface modules or engine interface modules lose demand from the station control
panel.