HTX30 Product Manual
Fault Finding
6-7
Name
SCP text
Description
Priority
Parameters
inconsistent
PARAM / INCON
Some of the parameters on this module are inconsistent with each
other.
Subcodes:
1 - User throttle calibration: The throttle calibration values are
inconsistent. The 40 %, 70 %, and 90 % values must be in
increasing order
101 - Ship throttle calibration: The throttle calibration values
are inconsistent. The 40 %, 70 %, and 90 % values must be in
increasing order
600 - Idle maximum: The maximum idle adjust RPM is
inconsistent with the minimum or maximum RPM
601 - Maximum RPM: The maximum RPM is inconsistent with
the minimum RPM
602 - RPM lookup: One of the RPM to throttle lookup is
inconsistent
Alarm
Character alarms
Name
SCP text
Description
Priority
Character ROM
error
CHAR / FAULT
Character ROM error, unable to read either due to corruption, or
missing
Subcodes:
0 - Params
1 - Factory defaults
2 - Ship defaults
3 - Id
4 - Param set
5 - Ship set
Alarm
Character ROM
changed
CHAR / CHANGE
The character ROM has been changed
Alarm
Character ROM
defaulted
CHAR / DEFLT
The character ROM has had a corruption, or was empty, it has
been defaulted to the modules best knowledge
Subcodes:
0 - Params
1 - Factory defaults
2 - Ship defaults
Alarm
JIM alarms
Name
SCP text
Description
Priority
Steering
feedback
STEER / FDBCK
Steering feedback out of range
Alarm
Reverse
feedback
REVRS / FDBCK
Reverse feedback out of range
Alarm
SCP demand
lost
DEMND / LOST
Loss of SCP demand
Alarm
Unable to steer
to port
STEER / STUCK
Follow up alarm steering to port
Alarm
Unable to steer
to starboard
STEER / STUCK
Follow up alarm steering to starboard
Alarm
Unable to
lower reverse
REVDN / STUCK
Follow up alarm reverse moving reverse duct down
Alarm
Unable to raise
reverse
REVUP / STUCK
Follow up alarm reverse moving reverse duct up
Alarm
JHPU
temperature
JHPU / TEMP
JHPU Temperature out of range
Warning
JHPU level
JHPU / LEVEL
JHPU oil level out of range
Warning
Bearing
temperature
BERNG / TEMP
Bearing temperature out of range
Warning