SAFETY INSTRUCTIONS
6
The device must be mounted on a support rail connected to protective conductor
potential. Both the support rail and the MP60/MP60DP module must be free of paint,
varnish and dirt at the place of installation.
To ensure adequate interference immunity, the bus cables (CAN and, for MP60DP,
PROFIBUS DP) must be shielded twisted pairs. The transducer cables must also be
shielded. To ensure immunity from interference, use only the Greenline shielding concept
(place the shield of the transducer cable onto the connector housing).
The cables used for the MP60/MP60DP digital inputs and outputs should not be longer
than 30 meters, and should not exit the building in which the system is located.
Otherwise it will not be possible to ensure that the device works without fault.
Strong electromagnetic fields or lightning strikes may lead to destruction.
When connecting cables (fitting and extracting terminals), measures must be taken to
prevent electrostatic discharge which could damage the electronics.
The MP60/MP60DP module must be operated with a separated extra-low voltage (18 to
30 V DC supply voltage), which usually supplies one or more consumers within a control
cabinet.
Should the device be operated on a DC voltage network
1)
, additional precautions must be
taken to discharge surge voltages.
Conversions and modifications
The MP60 and MP60DP modules must not be modified in their design or safety features
without our express consent. Any modification shall exclude all liability on our part for
any resulting damage.
In particular, any repair or soldering on motherboards is prohibited. When exchanging
complete modules, use only genuine parts from HBM.
The product is delivered from the factory with a fixed hardware and software
configuration. Changes can only be made within the scope documented in the manuals.
Qualified personnel
The modules are only to be deployed and used by qualified personnel, and always in
accordance with the technical data in conjunction with the safety rules and regulations
listed below.
This includes people who meet at least one of the three following requirements:
S As project personnel, you are familiar with the safety design features of the
automation equipment, and are accustomed to applying them.
S As automation plant operating personnel, you have been instructed on how to use the
equipment. You are familiar with the operation of the equipment and technologies
described in this documentation.
1) Wider-reaching electric power distribution system (e.g. across multiple control cabinets), possibly
also supplying consumers with high rated currents.