6 Using the heating system – Structure of the menus
113
i-11 Accumulator
Status
heating
Temp. top 77?
Temp. bottom 65?
Accumulator info
Accumulator status
Current temperature at top of accumulator
Current temperature at bottom of accumulator
i-12 Heat circuit 1
Heating
Supply: 34/19°C
Mixer: Off HCP: On
Information on heating circuit HC 1
Operating status of heating circuit 1
Supply temperature set/actual
Status of mixer Status of heat circulation pump
i-13 Heat circuit 2
Heating
Supply: 45/20°C
Mixer: Off HCP: On
Information on heating circuit HC 2
Operating status of heating circuit 2
Supply temperature set/actual
Status of mixer Status of heat circulation pump
i-14 Heat circuit 3
Heating
Supply: 34/19°C
Mixer: Off HCP: On
Information on heating circuit HC 3
Operating status of heating circuit 3
Supply temperature set/actual
Status of mixer Status of heat circulation pump
i-15 Heat circuit 4
Heating
Supply: 32/17°C
Mixer: Off HCP: On
Information on heating circuit HC 4
Operating status of heating circuit 4
Supply temperature set/actual
Status of mixer Status of heat circulation pump
i-16 Heat circuit 5
Heating
Supply: 45/19°C
Mixer: Off HCP: On
Information on heating circuit HC 5
Operating status of heating circuit 5
Supply temperature set/actual
Status of mixer Status of heat circulation pump
i-17 Heat circuit 6
Heating
Supply: 31/15°C
Mixer: Off HCP: On
Information on heating circuit HC 6
Operating status of heating circuit 6
Supply temperature set/actual
Status of mixer Status of heat circulation pump
i-18 DHW 1
Off DHW
Set: 60°C Pump:Off
Act: 50°C
Information on hot water tank 1
Operating status of hot water tank 1
Set temp. of hot water tank Status of pump
Current temperature of hot water tank
i-19 DHW 2
Off DHW
Set: 60°C Pump:Off
Act: 50°C
Information on hot water tank 2
Operating status of hot water tank 2
Set temp. of hot water tank Status of pump
Current temperature of hot water tank
i-20 Solar 1
Collector temp: 32°C
Solar pump 1: 60%
Solar acc. pump: 0%
Solar information
Solar collector temperature
Speed of solar pump 1
Solar acc. pump
No. Display Description
Table 6/2 - Information level

Table of Contents