116
1 - GENERAL
No. Display Description
Date and time
Tu; 09.09.2008
14:49:37
• Date and time
To set the day of the week and date.
To set the time.
1-00 General information
Show error
buffer
• Error buffer
Displays the last faults.
1-01 View
Boiler/HC module
HC module
• Display output
1-02 Keep embers glowing
no
yes
• Keep embers glowing
This is to switch between operation with automatic igni-
tion or sustaining the embers.
1-04 General information
Emergency mode on?
( 0) 0
• Emergency operation
Switches emergency operation on/off.
(0/1)
1-05 Fuel type
Fuel 1
Fuel 2
Fuel 3
pellets
• Fuel type
Selection of different parameter sets for various fuels.
1-06 General information
Operating parameters
save
( 0) 0
• Saving operating parameters
Current settings of parameters are stored in a separate
memory.
(0/1)
1-07 General information
Operating parameters
load
( 0) 0
• Load operating parameters
All settings will be overwritten by the database.
(0/1)
1-08 General information
Operating hours
reset?
( 0) 0
• Reset operating hours counter
The operating hours are reset.
(0/1)
1-09 General information
Initial commissioning
( 0) 0
• Initial commissioning
All settings are adopted from the HDG factory defauts.
(0/1)
Table 6/3 - System level / 1 - General