6 Using the heating system – Structure of the menus
132
7-19 Delivery system
Delivery system
reverse current
( 3.0) 3.0A
Delivery system
After exceeding the set motor current, the motor reverses
up to three times. Then a fault message is issued. (0.1 -
10.0 A)
7-21 Delivery system
Delivery system
reverse runtime
( 1) 1s
Delivery system
Reverse running time when the set reverse current is
exceeded.
(0 - 3 s)
7-23 Delivery system
Fill level indicator
Switch-off delay
( 60) 60s
Delivery system
Set the switch-off delay of the fill level indicator in the pel-
let vacuum container or at the dosage transition.
7-24 Delivery system
Fill level indicator
Switch-on delay
( 3) 3s
Delivery system
Set the switch-on delay of the fill level indicator in the
dosage transition.
7-25 Delivery system
Delivery system
Maximum runtime
( 25) 25m
Delivery system
Set the maximum runtime of the vacuum fan in the pellet
vacuum container.
7-26 Delivery system
Enable times
On 00:00 On 00:00
Off 24:00 Off 00:00
Enable times
Time block: Enable times for the delivery system can be
defined.
7-27 Delivery system
Fill after
Dosage runtime
( 200) 200m
Delivery system
After the set time has elapsed, the pellet vacuum contai-
ner is re-filled.
7-28 Delivery system
Vacuum fan supply
( 10) 10s
Delivery system
Set the supply time of the vacuum fan up to the start of
the pellet auger.
7-29 Delivery system
Vacuum fan lag time
( 10) 10s
Delivery system
Set the vacuum fan lag time after the full signal of the pel-
let vacuum container.
No. Display Description
Table 6/9 - System level / 7 - Delivery system