The zone acvates all the me. It is usually used in the sites
equipped with panic buon, smoke detector and glass-break
detector.
Fire Zone
The zone acvates all the me with sound/siren output
when alarm occurs. It is usually used in
re hazardous areas
equipped with smoke detectors and temperature sensors.
Gas Zone
The zone acvates all the me with sound/siren output
when alarm occurs. It is usually used in areas equipped with
gas detectors (e.g., the kitchen).
Medical Zone
The zone
acvates all the me with beep conrmaon when
alarm occurs. It is usually used in places equipped with
medical emergency
buons.
Timeout Zone
The zone acvates all the me. The zone type is used to
monitor and report the "ACTIVE" status of a zone, but it will
only report and alarm this status
aer the programmed me
has expired. (1 to 599) Seconds. It can be used in places
equipped with magnec contacts that require access but for
only a short period (e.g.,
re hydrant box's door or another
external security box door)
Disabled Zone
Alarms will not be acvated when the zone is triggered or
tampered. It is usually used to disable faulty detectors .
5.
Enable Stay Arming Bypass, Chime, or Silent Alarm according
to your actual needs.
Note
Some zones do not support the funcon. Refer to the actual
zone to set the funcon.
6.
Enable Enroll Wireless Detector , input the serial No., and set
the linked camera No.
Note
868 Devices do not support inpung serial No.
7.
Set the Disconnecn Duraon, and the system determins
connecon fault if the disconnected duraon of the device is
longer than the congured value.
8.
Click OK.
Note
Aer seng the zone, you can enter Status → Zone to view
the zone status.
Note
Under the System Opons of the Engineer Axiom Web
plaorm there is an opon called Early Alarm, this must be
disabled for Sweden.