8. MAINTENANCE OPERATIONS
8-11
8.3 Startup Suppression on Serious Failure Detection
This equipment suppresses startup of the equipment when one of the following incidents is
detected during Windows® startup in order to protect the hardware.
1. Fan failure
2. Remote shutdown signal input
< NOTE >
In the case of a remote shutdown signal input, startup is suppressed only when
“Enable automatic shutdown at remote shutdown input” is selected in the RAS
setting window. If a automatic shutdown is not selected, startup is not suppressed.
For information about how to use the RAS setting window, refer to “HF-W2000
Model 48/45 RAS FEATURES MANUAL”. When a remote shutdown signal input is
detected, the equipment displays a blue screen and then stops.
For information about the STOP error code of this case, see “9.3 STOP Error
Codes”.