2 Product Specification
Linear actuators MC55
Operating Manual Version 3.3 - November 2014 9
2.4 Technical data
Type MC55/24, MC55Y MC55/230
Supply voltage: 24 V AC ± 10%
24 V DC ± 10%
230 V AC + 6% -10%
115 V AC ± 10%
Power consumption 3,5 VA 7 VA
Weight 1.5 kg 1.5 kg
Dimensions See technical data sheets
Stroke MC55 max. 20 mm max. 20 mm
Frequency 50/60 Hz ± 5% 50/60 Hz ± 5%
Ambient temperature 0 to +60°C 0 to +60°C
Enclosure protection IP 54
IP 30 in manual mode
IP 54
IP 30 in manual mode
Operating mode S3-50% ED S3-50% ED
Actuating time 9 or 5 s/mm 9 or 5 s/mm
Actuating force 0.6 kN
During 24 V DC the
specified actuating force
can only be reached with
the help of an aligned AC
voltage.
0.6 kN
table 1 Technical data
Type MC55/24, MC55/230 MC55Y
Input signal Y/
Resistance of load
• Three-point • 0 … 10 V DC / 77 k
• 2 … 10 V DC / 77 k
• 0 … 20 mA / 510
• 4 … 20 mA / 510
Output signal X/
Load rating
• 0 … 10 V DC / resistance of load 1200 , I
max.
8
mA
Cable impedance between B1
and B2
• max. 10
table 2 Technical data signals