4 Assembly
Linear actuators MC160 • MC161 • MC163
Operating Manual Version 2.1 - March 2011 21
4.6 Fitting accessories
Accessories are not part of the scope of delivery for the linear actuator unless
expressly ordered! The linear actuators are prepared for retro-fitting with:
PCB for path switch (106)
PCB for output signal X=0/4 20 mA (111)
Hint: Optional operation with mA output signal or path switch possible
2.2 Accessories on page 7
4.6.1 Fitting a PCB for a path switch
WARNING
Risk of injury from electric shock by live parts!
When the power supply is on there is a danger of electric shock due to live parts.
Prior to commencing any work, ensure that the actuator is safely disconnected
from the power supply system.
Secure against unauthorised restarting.
1 Open the cover (201) of the linear actuator.
4.4 Assembling/disassembling the cover on page 16
224 V: Clipping the path switch PCB (106) to the safety catches on the cover
(201)
diagram 12 on page 21.
3230 V: Push the path switch PCB (106) onto the three spacers of (27) the push-
fit PCB (107).
4 Plug the female plug into the (115) path switch PCB (106) on the socket board
(123) of the main PCB (110). In the process pay attention to the notches on the
socket board and female plug.
27 Spacers
106 PCB for path switch
107 Push-fit PCB for 24 V or 230 V
115 Female plug
110 Main board
201 Cover for 24 V or 230 V
*
diagram 12 Assembling the path switch PCB inside the cover
107
27
115
106
110
201
24 V
230 V
201
110
106
115
201
27
106
115
110
107
201
106
115
110
24 V 230 V