5 Commissioning
Linear actuators MC100 • MC103
28 Version 2.1 - March 2011 Operating Manual
5.10 Commissioning
1 Check whether all fitting and assembly work has been competently finished.
4 Assembly on page 12
2 Ensure that the electrical actuation of the linear actuator can take place safely
without putting people or devices at risk.
3 Ensure that the linear actuator is attached correctly and that the cover of the
linear actuator is closed.
4.4 Assembling/disassembling the cover on page 14
4 Ensure that the linear actuator is set to automatic mode.
6.1 Changing between manual and automatic mode on page 29
5 Ensure that the operating parameters are set correctly.
5.1 Operating parameters and encoding switch settings on page 23
6 Ensure that the path measuring system is initialised.
5.9 Initialising the path measuring system on page 27
7 Apply supply voltage. The linear actuator will now move to the reference point.
The linear actuator is ready for operation.