254
lldp hold-multiplier
Syntax
lldp hold-multiplier value
undo lldp hold-multiplier
View
System view
Default level
2: System level
Parameters
value: Sets the TTL multiplier, ranging from 2 to 10.
Description
Use lldp hold-multiplier to set the TTL multiplier.
Use undo lldp hold-multiplier to restore the default.
By default, the TTL multiplier is 4.
You can set the TTL of the local device information by configuring the TTL multiplier.
The TTL configuration of a device is determined by the following expression:
TTL multiplier × LLDPDU transmit interval
The TTL can be up to 65535 seconds. Longer TTLs will be rounded off to 65535 seconds.
Related commands: lldp timer tx-interval.
Examples
# Set the TTL multiplier to 6.
<Sysname> system-view
[Sysname] lldp hold-multiplier 6
lldp management-address-format string
Syntax
lldp management-address-format string
undo lldp management-address-format
View
Layer 2 Ethernet interface view, Layer 3 Ethernet interface view, port group view
Default level
2: System level
Parameters
None
Description
Use lldp management-address-format string to encapsulate the management address in the form of
strings in TLVs.

Table of Contents

Other manuals for HP 5500 HI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5500 HI Series and is the answer not in the manual?

HP 5500 HI Series Specifications

General IconGeneral
BrandHP
Model5500 HI Series
CategorySwitch
LanguageEnglish

Related product manuals