Left PCM is connected AC power.InfoUser
sysTempMon: Power for
Left PCM Plugged-in
152133
Left PCM is not connected to AC power (un-
plugged).
InfoUser
sysTempMon: Power for
Left PCM Un-plugged
152134
Right PCM is connected AC power.InfoUser
sysTempMon: Power for
Right PCM Plugged-in
152135
Right PCM is not connected to AC power (un-
plugged).
InfoUser
sysTempMon: Power for
Right PCM Un-plugged
152136
Left PCM (#1) is reporting a faulty fan.InfoUser
sysTempMon: Slot 1 (R1)
PCM Fan%d faulty
152137
Left PCM (#1) is reporting a healthy fan.InfoUser
sysTempMon: Slot 2 (R2)
PCM Fan%d faulty
152138
Right PCM (#2) is reporting a faulty fan.InfoUser
sysTempMon: Slot 1 (R1)
PCM Fan%d healthy
152139
Right PCM (#2) is reporting a healthy fan.InfoUser
sysTempMon: Slot 2 (R2)
PCM Fan%d healthy
152140
Router has detected an over temperature,
Front: %dC Rear: %dC CPU1: %dC CPU2: %dC.
InfoUser
sysTempMon: Over Temperat-
ure Front: %dC Rear: %dC
CPU1: %dC CPU2: %dC
152141
Fan(s) speed has been set to high.InfoUser
sysTempMon: Setting the
fan speed to high
152142
Fan(s) speed has been set to normal.InfoUser
sysTempMon: Setting the
fan speed to normal
152143
Router temperature has returned to normal
operating range, Front: %dC Rear: %dC CPU1:
%dC CPU2: %dC.
InfoUser
sysTempMon: Temperature
back to safe value.
Front: %dC Rear: %dC
CPU1: %dC CPU2: %dC
152144
Router has reached a critical temperature ad
is shutting down, Front: %dC Rear: %dC CPU1:
%dC CPU2: %dC.
InfoUser
sysTempMon: Critical Tem-
perature, Shutting Down
Front: %dC Rear: %dC
CPU1: %dC CPU2: %dC
152145
A GE port (eth#%d) has invalid NVRAM
parameters.
FatalTOE
QL3022:ql3xxx_probe: Ad-
apter eth#%d, Invalid NV-
RAM parameters
200721
Uncorrectable memory error detected at ad-
dress provided in log message.
Fatal
Sys-
tem
"memory monitor: Detected
Uncorrectable Ecc %08lx
system is rebooting in 5
secs\n"
233473
Attempt to register the interrupt handler failed.Fatal
Sys-
tem
"Failed to register inter-
rupt handler!\n"
233474
Failed class_simple_create system call
from memory monitor initialization routine.
Fatal
Sys-
tem
"%s class_simple_create
failed\n"
233475
MPX200 Multifunction Router 225