Details and SolutionDescriptionEvent code
Power cycle the device and retry the
operation.
VPD data recovery.92
Verify that the fan for the indicated drive sled
is operational and not obstructed.
NOTE:
The fan only operates when cooling is
required.
External drive cooling fan failure (fan motion
has stopped). The subcode indicates which
drive sled fan is affected.
Subcode 00: drive sled #1
Subcode 01: drive sled #2
etc.
DB
Verify that the fan for the indicated power
supply is operational and not obstructed.
Upgrade to the latest version of Library
firmware.
If the problem continues, replace the
power supply
Power supply cooling fan failure. Power
supply x fan has failed. Redundancy may be
at risk. (MSL8048 and MSL8096 only)
The subcode indicates which power supply
fan is affected.
Subcode 00: lower power supply
Subcode 01: upper power supply
DD
Power supply x has failed. Redundancy is not
available. (MSL8048 and MSL8096 only)
The subcode indicates which power supply
fan is affected.
Subcode 00: lower power supply
Subcode 01: upper power supply
DE
Verify that the power supply is correctly
inserted and that the thumbscrews are
tightened.
Power cycle the device.
If the problem continues, contact HP cus-
tomer support.
One of the redundant power supplies has
failed. Redundancy is not available.
(MSL4048 only)
The subcode indicates which power supply
fan is affected.
Subcode 00: lower power supply
Subcode 01: upper power supply
DF
Verify that the power supplies in the Lib-
rary are inserted correctly and that the
thumbscrews are adjusted.
Check the AC power cable connections.
NOTE:
The MSL2024 does not have a redundant
power supply option.
Power supply redundancy not available in
the master Library.
E9
Power supply redundancy not available in
the lower Library.
EA
Power cycle the device and retry the op-
eration.
Re-seat the tape drive to ensure a good
connection to the device.
MSL8048 and MSL8096: Verify that the
drive is installed in one of the four loca-
tions that has a drive connector.
Drive sled missing.F2
Troubleshooting212