To replace the component, reverse the removal procedure.
Removing and replacing a type-p storage controllerRemoving and replacing a type-p storage controller
About this taskAbout this task
WARNING:WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove power from the server
by removing the power cord. The front panel Power On/Standby button does not shut off system power. Portions of the
power supply and some internal circuitry remain active until AC power is removed.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
4. Remove the access panel .
5. Remove the riser cage:
Remove the primary riser cage.
Remove the secondary riser cage.
6. Disconnect any cables from the storage controller.
Note the connection for each cable.
7. Remove the storage controller from the riser.