WARNING:WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to
cool before touching them.
WARNING:WARNING:
To reduce the risk of fire or burns after removing the energy pack:
Do not disassemble, crush, or puncture the energy pack.
Do not short external contacts.
Do not dispose of the energy pack in fire or water.
Do not expose the energy pack to low air pressure as it might lead to explosion or leakage of flammable liquid or gas.
Do not expose the energy pack to temperatures higher than 60°C (140°F).
After power is disconnected, battery voltage might still be present for 1s to 160s.
CAUTION:CAUTION:
Protect the server from power fluctuations and temporary interruptions with a regulating UPS. This device protects the
hardware from damage caused by power surges and voltage spikes and keeps the server in operation during a power
failure.
CAUTION:CAUTION:
To prevent damage to electrical components, properly ground the server before beginning any installation, removal, or
replacement procedure. Improper grounding can cause electrostatic discharge.
CAUTION:CAUTION:
To avoid data loss, Hewlett Packard Enterprise recommends that you back up all server data before installing or removing
a hardware option, or performing a server maintenance or troubleshooting procedure.
CAUTION:CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server in this
manner results in improper airflow and improper cooling that can lead to thermal damage.
Rail identification markersRail identification markers
The rack rail option support is dependent on these two factors:
The height and weight of the chassis as determined by the front- and rear-end server configurations.
The depth of the chassis as measured from the edge of the front panel (without the front bezel) to the edge of the rear panel.
To ensure compatibility between the rack rails and the server, verify that the rail number labels on the chassis match the ones stamped on
the rails.
Rail number labels on the chassis
HPE ProLiant DL380 Gen11 Server Maintenance and Service Guide 46