2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
4. Remove the access panel .
CAUTION:CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server in
this manner results in improper airflow and improper cooling that can lead to thermal damage.
5. Remove the fan cage.
IMPORTANT:IMPORTANT: For optimum cooling, install fans in all primary fan locations.
ResultsResults
To replace the component, reverse the removal procedure.
Removing and replacing the OCP 3.0 adapter blankRemoving and replacing the OCP 3.0 adapter blank
About this taskAbout this task
WARNING:WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove power from the server
by removing the power cord. The front panel Power On/Standby button does not shut off system power. Portions of the
power supply and some internal circuitry remain active until AC power is removed.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.