EasyManua.ls Logo

HPE ProLiant MicroServer Gen10 Series

HPE ProLiant MicroServer Gen10 Series
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error message Description
Error: Thermal temperature condition has been
degraded, the system may or may not shut down
depending on thermal shutdown setting.
Either the environmental temperature or the internal
system temperature has triggered a warning
condition.
If the Thermal Shutdown option is enabled in the
Aptio Setup Utility, the system will automatically
initiate a graceful shutdown to protect the system. To
check, access the Aptio Setup Utility. Then, select
Advanced > Hardware Health Configuration.
See Fan and thermal issues.
Warning: System was probably shut down due to the
thermal temperature condition being set to degraded
at last boot.
Either the environmental temperature or the internal
system temperature triggered a warning condition
when the system was last powered on.
If the Thermal Shutdown option was enabled and
the OS power button is set to shut down the system,
a graceful shutdown occurred to protect the system.
See Fan and thermal issues.
Warning: System was shut down due to thermal
temperature condition being set to failed at last boot.
Either the environmental temperature or the internal
system temperature triggered a failed condition when
the system was last powered on. The system shuts
down immediately for protection.
See Fan and thermal issues.
Warning: Power fault detected at last boot.
A power fault event was detected during the last
boot.
See Power issues.