MONT20 Common Function List
Functions Function Description Remarks
Syn. and Asyn.
integrated control
MONT20 door motor integrated controller can drive AC Asyn. motor and permanent
magnet Syn. motor.
F00.06
Self-adaptive
door opening
holding torque
The output torque keeps the door system dynamic balance: Reduce the energy
consumption in the door opening state, and enhance self-adaptive OD holding
torque function.
F10.06
Automatic
generation of
switch door curve
Through the feedback position of the current encoder, the door vane position and
the door width learned from the door width, the running speed is automatically
selected and the door is switched.
F10.05
Speed
control/distance
control
Support two modes of operation: Speed control and distance control. F00.02
Automatic demo
running
In the demo mode, press the door open or close key, the controller will automatically
cycle the door according to the switch door curve. Instruct to press stop/fault reset
key, end the demo running, and record the number of demo runs.
F00.03
Automatic
recognition and
flexible handling
in case of
obstruction
According to the setted torque, the system judges the resistance torque during the
process of door opening or closing.
If the door is blocked, it can be set as two ways: Blocked re-opening and output
blocked signal controlled by elevator system.
If the door is blocked, open and shut down and output blocked signal can be
controlled by elevator system.
F10.07
Automatic
recognition of
encoder direction
The direction of the encoder and the phase sequence of the output are automatically
recognized during the tuning process. Simply change the parameters to change the
running direction.
F02.01
Adaptive grid
voltage
fluctuation
The grid voltage fluctuation will be detected in real time during the running of the
door motor, and the controller will automatically adjust output voltage according to
bus voltage fluctuation; When the grid surge voltage is detected, the control system
will automatically reset the overvoltage fault and put it back into running.
F06.13
unit
Controller
running record
Automatically accumulate running time, and the number of switching door.
F09.13 -
F09.16
Parameter copy The parameters can be uploaded and downloaded through the optional keypad. F00.01