Parameter
Index
Meaning Default Setting
29 Hotline ringing parameters (0~255). For configuring
this parameter, refer to the initial and cadence ringing
types of the V5 interface.
0
30 Length of timer for line card send on-hook message
after howler tone (ms).
1000 ms
31 Reserved parameters 65535
32 Flag of checking V5 free timeslot when caller off-hook.
0: not check; 1: check
0: not check
33 Flag of DSL port sending deactive signal to LE after
V5 switch-over. 0: not send; 1: send
0: not send
34 Power of the comfortable noise. 0~90 correspond to
0~-90 db.
60
35 Flag of DSP chip working mode. 0: normal; 1:
intelligent public telephone (IPT); 2: NLP enhanced; 3:
NLP decreased; 4: NLP closed; 5: DTMF EC
0: normal
36 Flag of Z interface extension dynamic timeslot
allocation. 0: Not dynamically allocate timeslot; 1:
Dynamically allocate timeslot
0: Not
dynamically
allocate timeslot
37 Flag of whether the current is limited when the
subscriber port is locked. 0: not limited; 1: limited
0: not limited
38-39 Reserved parameters 65535
40 Short-circuit current protection threshold on the E1
port, which is valid for only the SA586 chip. 1: 140 mA;
2: 165 mA; 3: 190 mA; 4: 215 mA
1: 140 mA
41 Flag of the exchange re-assigning the timeslot when the
V5 PSTN is restarted. 0: re-assign; 1: not re-assign
1: not re-assign
42 Timeout time of PPP negotiation (0~300 s) 10 s
43 Flag of stop dialtone when pulse dial the first telephone
number. 0: not stop; 1: stop
0: not stop
44-47 Reserved parameters 65535
48 The time length of the meter test timer (10~65535 min) 65535 min