MERCHANDISER SETTINGS (Cont'd)
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 • Printed in USA
Revised March 1, 1997 P/N 340272A
8 - 15
Models
For all Merchandisers
with Gravity Coils, the
Temperature listed in
the "Discharge A i r "
row is P ro d u c t
Temperature.
Refrigeration
D i s c h a rge Air
Te m p e r a t u r e˚ F
Evaporator
Temperature˚F
Fan Cycling
CI/CO ˚F
Defrost
Frequency
Electric
Temp Te r m ˚ F
Failsafe Min
Reverse Air
Temp Te r m ˚ F
Failsafe Min
K o o l g a s
Duration Min
O ff t i m e
Temp Te r m ˚ F
Duration Min
FHM
FHMG
FHMH
FHMGH
FHMS
FHMSG
MHF
MHFG
MHFGH
NM3
NM3G
NM4
NM4G
NDD3
NDD3G
NDD4
NDD4G
22˚ F
11˚ F
28/38˚ F
6 Hrs
48˚ F
46 Min
14 Min
46 Min
CGDMG
CGDMGT
CSDMG
NEGDF
NEGSF
NEGDT
NEGDH
24˚ F
21˚ F
24 Hrs
48˚ F
90 Min
14 Min
90 Min
CGDM
CSDM
NEBDH
NEBSH
24˚ F
20˚ F
24 Hrs
54˚ F
40 Min
24 Min
90 Min
FM
FMG
FMV
FMGV
FMGC
VFMGC
FMGCD
NM1
NM1G
22˚ F
17˚ F
28/38˚ F
12 Hrs
48˚ F
46 Min
48˚ F
70 Min
14 Min
70 Min
FMR
FMRV
FMRG
FMRGV
FMRGC
22˚ F
9˚ F
28/38˚ F
12 Hrs
48˚ F
46 Min
48˚ F
70 Min
14 Min
70 Min
GF
GFI
GG
GWIT
GWI
GTF
GWI6
GFFS
NF1
NF1N
NFN
NFW
NFCW
NFWE
NFCWE
NFFS
24˚ F
18˚ F
24 Hrs
52˚ F
60 Min
48˚ F
60 Min
20 Min
MWI
MWI6
22˚ F
10˚ F
8 Hrs
48˚ F
60 Min
14 Min
60 Min
VGL
VGK
VGS
VGLR
VGSR
NVGB
NVGC
NVGA
24˚ F
22˚ F
24 Hrs
48˚ F
110 Min
110 Min
CGDM
CSDM
NEBDH
NEBSH
26˚ F
22˚ F
24 Hrs
100 Min
Application MEAT DELI