MERCHANDISER SETTINGS (Cont'd)
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 • Printed in USA
CONTROL SETTINGS Revised March 1, 1997
8 - 16
Models
For all Merchandisers
with Gravity Coils, the
Temperature listed in
the "Discharge A i r "
row is P ro d u c t
Temperature.
Refrigeration
D i s c h a rge Air
Te m p e r a t u r e˚ F
Evaporator
Temperature˚F
Fan Cycling
CI/CO ˚F
Defrost
Frequency
Electric
Temp Te r m ˚ F
Failsafe Min
Reverse Air
Temp Te r m ˚ F
Failsafe Min
K o o l g a s
Duration Min
O ff t i m e
Temp Te r m ˚ F
Duration Min
DMD
DMDH
DMDA
NDD5
NDD5H
NDD5A
32˚ F
18˚ F
6 Hrs
48˚ F
40 Min
14 Min
40 Min
RDM
RDMH
30˚ F
20˚ F
24 Hrs
12 Min
60 Min
CWI
CWI6
MWI
MWI6
30˚ F
20˚ F
6 Hrs
14 Min
56 Min
FHM
FHMG
FHMH
FHMGH
FHMS
FHMSG
MHF
MHFG
MHFGH
NM3
NM3G
NM4
NM4G
NDD3
NDD3G
NDD4
NDD4G
32˚ F
20˚ F
28/38˚ F
6 Hrs
48˚ F
40 Min
14 Min
40 Min
FM
FMG
FMV
FMGV
FMGC
VFMGC
FMGCD
NM1
NM1G
30˚ F
25˚ F
28/38˚ F
12 Hrs
48˚ F
70 Min
14 Min
70 Min
RMA
RMFA
NRD
NRFL
NRDV
NRFLV
30˚ F
23˚ F
24 Hrs
12 Min
60 Min
VBL
VBS
VBK
VBT
NVBA
NVBB
NVBC
34˚ F
20˚ F
24 Hrs
60 Min
VGL
VGK
VGS
VGLR
VGSR
NVGB
NVGC
NVGA
38˚ F
20˚ F
24 Hrs
110 Min
CGDMG
CGDMGT
CSDMG
NEGDF
NEGSF
NEGDT
25˚ F
21˚ F
24 Hrs
90 Min