MERCHANDISER SETTINGS (Cont'd)
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 • Printed in USA
Revised March 1, 1997 P/N 340272A
8 - 17
Models
For all Merchandisers
with Gravity Coils, the
Temperature listed in
the "Discharge A i r "
row is P ro d u c t
Temperature.
Refrigeration
D i s c h a rge Air
Te m p e r a t u r e˚ F
Evaporator
Temperature˚F
Fan Cycling
CI/CO ˚F
Defrost
Frequency
Electric
Temp Te r m ˚ F
Failsafe Min
Reverse Air
Temp Te r m ˚ F
Failsafe Min
K o o l g a s
Duration Min
O ff t i m e
Temp Te r m ˚ F
Duration Min
JVMR
JVMRS
29˚ F
15˚ F
6 Hrs
60 Min
RMFA
NRFL
NRFLV
30˚ F
23˚ F
24 Hrs
12 Min
60 Min
DMZ
DMZA
DMZH
DMX
DMXA
DMXH
ND5LZ
ND5Z
ND5HZ
ND5LX
ND5X
ND5HX
32˚ F
21˚ F
8 Hrs
48˚ F
40 Min
14 Min
40 Min
RDM
32˚ F
25˚ F
24 Hrs
12 Min
60 Min
RMA
RMFA
NRD
NRDV
NRFL
NRFLV
34˚ F
27˚ F
24 Hrs
12 Min
60 Min
Bulk
PRO
PHSM
PH
PHRO
P
NP1
NP2
37˚ F
21˚ F
6 Hrs
12 Min
40 Min
Pack
PRO
PHSM
PH
PHRO
P
NP1
NP2
33˚ F
18˚ F
6 Hrs
12 Min
40 Min
PVWI
PWI
PWIRO
EPWI
PVWI6
PWI6
PWIRO6
EPWI6
33˚ F
20˚ F
8 Hrs
46 Min
CGBR
NEBBDT
30˚ F
18˚ F
12 Hrs
40 Min
Application DAIRY F L O R A L PRODUCE B A K E RY