Machine Maintenance: 10-2
Daily
Check engine oil level.
Empty recovery tank inlet lter.
Inspect and clean garden hose screen.
Visually inspect machine for loose wires, oil leaks, water leaks, etc.
Inspect recovery tank stainless steel lter for clogging or damage; clean, repair or
replace as needed.
Inspect and clean the vacuum slot on the cleaning wand. Watch for sharp edges that
may tear the carpet; remove any sharp edges as required.
Lubricate blower with a HydraMaster-recommended spray lubricant
(P/N 000-087-006) through blower lube port.
Park the vehicle inside or turn on heater during freezing weather.
Weekly
Check around vehicle and CDS unit for any evidence of oil/uid leaks.
Grease, oil, antifreeze, and debris build-up near hot equipment, such as the
vehicle engine exhaust system or the CDS blower exhaust system, can present
a re hazard and can cause death or bodily injury.
Vehicle engine exhaust system or the CDS blower exhaust system, can present
a re hazard and can cause death or bodily injury.
Clean and inspect oat switches.
Flush water and chemical system with 50/50 white vinegar solution.
Change pump oil after rst 50 hours; every 300 hours thereafter.
Check pump oil. Add as necessary.
Check pump drive belt for wear.
Check pump pulleys for wear.
Check CDS blower mounting fasteners, drive shaft clamping collar fasteners, and
CDS front end component fasteners, tighten as needed.
Check internal machine high pressure water lines for wear or chang.
Remove and clean chemical container.
Clean and inspect recovery tank inlet lter.
Inspect and clean vacuum relief valve.

Table of Contents