10-3: Machine Maintenance
Inspect all external solution hoses, vacuum hoses, and quick connects for wear or
damage that may cause premature failure, replace as needed.
Clean recovery tank thoroughly with high pressure washer.
Check vehicle engine rpm on CDS tachometer:
Speed 1 = 1,500
Speed 2 = 1,400
Speed 3 = 1,300
Monthly
Check engine air cleaner lter. Clean as necessary.
Check blower drive belt.
Clean and inspect battery connections as needed.
Change blower oil after rst 100 hours.
Quarterly
Check chemical pump, chemical pump valves and diaphragm.
Change oil in blower every 400 - 500 hours.
Change oil in pump every 300 hours. Replace pump drive belt (P/N 000-010-065)
every 300 hours.
Check the CDS wiring harness for any chang or wear, especially in the vehicle engine
compartment or near any rotating parts.
Check the vehicle wiring harness for any chang or wear, especially in the vehicle
engine compartment or near any rotating parts.
Grease the power pack pillow block bearings.
Every 500 Hours
Grease drive shaft U-joints, splines and zerks.
Clean and inspect Salsa Heat exchanger (if equipped).
Yearly
Give van complete vehicle service.
Flush the van’s cooling system. Add new anti-freeze.
Change the van’s transmission uid.
Change engine oil and lter after every 2,000 miles.