Diagnostic Action
Control
8.
Press Forms Feed switch.
r,Panel
Do forms advance?
YES:
Go to step
9.
NO:
Measure for approximately +4
to
5.5 Vdc
on
pin 6
of
Control Panel.
Use
pin 8 for ground (see Section 5,
"Locations").
5 Vdc?
NO:
Replace
both
Control cards
(see Section
3, "Removal/
Replacement").
YES:
Press and hold Forms Feed
switch. Measure
0 to + 1.5 Vdc
on pin 6
of
Control Panel.
",......
1.5
Vdc?
YES:
Replace both Control
cards (see Section
3,
"Removal/
Replacement").
NO:
Replace Control Panel
(see Section
3,
"Removal/
Replacement") .
",......