Table 10. Fault Messages (continued)
Fault Message
Operator
Correctable? Explanation Solution
062 EXHAUST FAN CHECK
SEE USER’S MANUAL
Yes Sensors cannot detect current
in fan circuit.
Power off the printer. Check for
obstruction of vents and fan
airway; remove any
obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on
the printer. If this message
reoccurs, contact your IBM
service representative.
Note: This message should not
appear on a Pedestal model. If
this message does appear,
contact your IBM Service
Representative.
065 HAMMER FAN CHECK*
SEE USER’S MANUAL
Yes Sensors cannot detect current
in fan circuit.
Power off the printer. Check for
obstruction of vents and fan
airway; remove any
obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on
the printer. If this message
reoccurs, contact your IBM
service representative.
069 DATA CLEARED N/A Appears when data is
cleared out of printer after
Cancel key has been pressed.
No action necessary.
080 POWER SUPPLY HOT No Power supply temperature is
elevated beyond normal
threshold.
Contact your IBM service
representative.
081 POWER VOLT CHECK*
SEE USER’S MANUAL
No Power supply voltage failure. Contact your IBM service
representative.
082 POWER 8.5V CHECK*
SEE USER’S MANUAL
No Internal power failure. Contact your IBM service
representative.
083 INTAKE FAN CHECK*
SEE USER’S MANUAL
Yes Sensors cannot detect current
in fan circuit.
Power off the printer. Check for
obstruction of vents and fan
airway; remove any
obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on
the printer. If this message
reoccurs, contact your IBM
service representative.
084 POWER 48V CHECK*
SEE USER’S MANUAL
No Controller voltage failure. 15
V failure on the controller
board.
Contact your IBM service
representative.
085 CONTROL VOLT CHECK
SEE USER’S MANUAL
No Controller voltage failure. Contact your IBM service
representative.
086 CONTROL 15V CHECK*
SEE USER’S MANUAL
No Controller voltage failure. Contact your IBM service
representative.
Chapter 6. Routine Service and Diagnostics 235